Analisis Stabilitas Glukosa, Trigliserida Dan Albumin Pada Pooled Serum
Sari
ABSTRACT
The use of pooled sera made from leftover patient samples is one alternative to reduce laboratory quality control costs. Researchers aim to determine the stability of pooled serum as a control material for the parameters glucose, triglycerides and albumin. descriptive research with literature review method. The data source used is secondary data. The main source of article search by SINTA- Science and Technology. Analysis of the results used in this study is an analytical method. Month 1 CV glucose levels using pooled serum 5.31%, on commercial serum 7.91%. Month 2 pooled serum 4.87%, commercial serum 6.9%. Month 3 CV pooled serum 2.33%, commercial serum 4.61%. Month 1 CV of triglyceride using pooled serum 1.84%, commercial serum 3.47%. Month 2 pooled serum 1.63%, commercial serum 3.71%. Month 3 CV pooled serum 1.79%, commercial serum 3.30%. Month 1 CV results of albumin levels using pooled serum 5.66%, commercial serum 5.69%. Month 2 CV pooled serum 4.46% and commercial serum 6.32%. Month 3 CV on pooled serum 4.85%, commercial 5.72%. Based on the results of the examination of glucose, triglyceride and albumin levels using pooled serum stored at -20 oC, the results were quite stable in the parameters of triglycerides and albumin.
Keywords: Albumin, Glucose, Pooled Serum, Stability, Triglycerides
ABSTRAK
Pemakaian pooled serum yang terbuat dari sisa sampel pasien merupakan salah satu alternatif untuk mengurangi biaya pengendalian mutu laboratorium. Peneliti bertujuan mengetahui kestabilan pooled serum sebagai bahan kontrol pada parameter glukosa, trigliserida dan albumin. Penelitian desktiptif menggunakan metode literature review. Sumber data yang digunakan merupakan data sekunder. Sumber pencarian artikel utama oleh SINTA- Science and Technology. Analisis data yang digunakan pada penelitian menggunakan metode analitik. CV bulan1 kadar glukosa menggunakan pooled serum 5.31 %, pada serum komersial 7.91%. Bulan 2 pooled serum 4.87 %, serum komersial 6.9%. Bulan 3 CV pooled serum 2.33 % , serum komersial 4.61 %. Bulan 1 CV trigliserida menggunakan pooled serum 1.84%, serum komersial 3.47%. Bulan ke 2 pooled serum 1.63%, serum komersial 3.71%. Bulan 3 CV pooled serum 1.79%, serum komersial 3.30%. Hasil CV bulan 1 kadar albumin menggunakan pooled serum 5.66%, serum komersial sebesar 5.69%. Bulan ke 2 CV pooled serum 4.46% dan serum komersial 6,32%. Bulan ke 3 CV pada pooled serum 4.85% ,komersial 5.72%. Berdasarkan hasil pemeriksaan kadar glukosa, trigliserida dan albumin menggunakan pooled serum yang disimpan pada suhu -20oC menunjukkan hasil yang cukup stabil pada parameter trigliserida dan albumin.
Kata Kunci: Albumin, Glukosa, Pooled Serum, Stabilitas, Trigliserida
Teks Lengkap:
Download ArtikelReferensi
Afriayani, I., Wulandari, N., Teknologi Laboratorium Medis, (2023). Perbandingan Kadar Trigliserida Pada Serum Segera Diperiksa Dan Ditunda 7 Hari Pada Suhu 2-8 °C. Jurnal Analis Kesehatan Klinikal Sains (Vol. 11, Issue 2). Http://Jurnal.Univrab.Ac.Id/Index.Php/Klinikal
Hartini, S., Suryani, M. E., Kesehatan, P., & Kaltim, K. (2016). Uji Kualitas Serum Simpanan Terhadap Kadar Kolesterol Dalam Darah Di Poltekkes Kemenkes Kaltim. 2(1), 65–69.
Handayati, A., Christyaningsih, J., & Rini, T. (2014). Uji Stabilitas Pooled Sera Yang Disimpan Dalam Freezer Untuk Pemantapan Mutu Internal Di Laboratorium Klinik. Jurnal Penelitian Kesehatan, 12(1).
Hedayati, M., Razavi, S. A., Boroomand, S., & Kheradmand Kia, S. (2020). The Impact Of Pre-Analytical Variations On Biochemical Analytes Stability: A Systematic Review. In Journal Of Clinical Laboratory Analysis (Vol. 34, Issue 12). Https://Doi.Org/10.1002/Jcla.23551
Jamtsho, R. (2013). Stability Of Lyophilized Human Serum For Use As Quality Control Material In Bhutan. Indian Journal Of Clinical Biochemistry, 28(4), 418–421. Https://Doi.Org/10.1007/S12291-013-0328-X
Jiskani, S. A., Pirzado, A. A., Saleem, M. W., Naz, L., Shaikh, A., & Atzaz, N. (2021). Determination Of Pooled Serum As A Better And Cheap Method For Internal Quality Control In Clinical Laboratory. Linguistica Antverpiensia, 2564-2571
Kachhawa, K., Kachhawa, P., Varma, M., Behera, R., Agrawal, D., & Kumar, S. (2017). Study Of The Stability Of Various Biochemical Analytes In Samples Stored At Different Predefined Storage Conditions At An Accredited Laboratory Of India. Journal Of Laboratory Physicians, 9(01), 011–015. Https://Doi.Org/10.4103/0974-2727.187928
Kulkarni, S., Pierre, S. A., & Kaliaperumal, R. (2020). Efficacy Of Pooled Serum Internal Quality Control In Comparison With Commercial Internal Quality Control In Clinical Biochemistry Laboratory. Journal Of Laboratory Physicians, 12(03), 191–195. Https://Doi.Org/10.1055/S-0040-1721151
Mahardika, F. T., Astuti, S. S. E., & Krihariyani, D. (2016). Pengaruh Lama Dan Suhu Penyimpanan Pooled Sera Terhadap Stabilitas Kadar Glukosa Dan Asam Urat. Analis Kesehatan Sains, 5(1).
Merdekawati, F. (2019). Reagen Buatan Sendiri Sebagai Reagen Alternatif Untuk Pemeriksaan Kadar Albumin. Meditory: The Journal Of Medical Laboratory, 7(2).
Muhammad, M., Yayuk, K., & Endah, Y. (2015). Pemanfaatan Pool Serum Sebagai Bahan Kontrol Ketelitian Pemeriksaan Glukosa Darah. Medical Laboratory Technology Journal. Banjarmasin
National Accreditation Board For Testing And Calibration Laboratories (Nabl). 2019. Specific Criteria For Accrefitatic Medical Laboratories. Nabl-112_Issue-No.-04.Pdf (Nabl-India.Org)
Permenkes. (2013). Tentang Cara Penyelenggaraan Laboratorium Klinik. Nomor 43. Pmk No. 43 Ttg Penyelenggaraan Laboratorium Klinik Yang Baik.Pdf (Kemkes.Go.Id)
Preethi, L., Sampath G, & Saravanan R. Alternative Method For Uninterrupted And Inexpensive Control Process In Clinical Biochemistry Laboratory. Https://Doi.Org/10.24327/Ijcar.2019
Ramdhani, F. H., Purbayanti, D., & Astuti, P. (2023). Uji Stabilitas Pooled Sera Yang Disimpan Di Suhu 2-8ºc Pada Pemeriksaan Albumin: The Pooled Sera Stability Test Is Stored At A Temperature Of 2-8ºc On Albumin. Borneo Journal Of Medical Laboratory Technology, 6(1), 371-375.
Salma, F. D., Rahayu, I. G., Rinaldi, S. F., & Kurnaeni, N. (2019). Cost-Effectiveness Analysis (Cea) Bahan Kontrol Komersial Dan Pool Serum Pasien. Jurnal Riset Kesehatan Poltekkes Depkes Bandung, 11(1), 293-298
Samsudin, R. R. (2021). The Effect Of Storage Time For Pooled Sera On Freezers On The Quality Of Clinical Chemical Examination. The Effect Of Storage Time For Pooled Sera On Freezers On The Quality Of Clinical Chemical Examination, 4(2), 78-8
Syamsudin, A. R., Solihat, M. F., & Kurnaeni, N. (2023). Stabilitas Pooled Sera Dengan Penambahan Propilen Glikol, Etilen Glikol Dan Natrium Azida Sebagai Bahan Kontrol Alternatif. Jurnal Riset Kesehatan Poltekkes Depkes Bandung, 15(1), 128–135. Https://Doi.Org/10.34011/Juriskesbdg.V15i1.2187
Zheng, R., Brunius, C., Shi, L., Zafar, H., Paulson, L., Landberg, R., & Naluai, T. (2021). Prediction And Evaluation Of The Effect Of Pre-Centrifugation Sample Management On The Measurable Untargeted Lc-Ms Plasma Metabolome. Analytica Chimica Acta, 1182. Https://Doi.Org/10.1016/J.Aca.2021.338968terupdate.
DOI: https://doi.org/10.33024/mahesa.v4i11.16205
Refbacks
- Saat ini tidak ada refbacks.
Publisher: Universitas Malahayati Lampung
Semua artikel dapat digunakan dibawah lisensi Creative Commons Attribution-ShareAlike 4.0 International License
kostenlose besucherzähler