Perbandingan Jumlah Trombosit Pada Sampel Darah 3 ML, 2 ML, & 1 ML Dengan Antikoagulan K2EDTA Setelah Ditunda 4 Jam Di RSUD. Dr. H. Abdul Moeloek Bandar Lampung

Syuhada Syuhada, Abdurrahman Izzudin, Tusy Triwahyuni, Bella Tania Putri

Sari


ABSTRACT

 

Insufficient sample volume and delay can increase blood clotting; besides can cause platelets aggregation (stick to one another). Objectives: to determine whether there is a difference between the results of the hematology test of the platelet count in the volume of 3 ml, 2 ml, and 1 ml blood samples with K2EDTA anticoagulant after being postponed 4 hours. This study used an observational analytic method with a cross sectional design. The mean results of the platelet count in 1 ml and 2 ml of blood volume in the K2EDTA vacutaier tube which are postponed for 4 hours are higher than the platelet count in 3 ml of blood volume. Conclusion: There is no significant difference in the number of platelets in 3 ml, 2 ml, and 1 ml blood samples in the K2EDTA vacutainer tube after being postponed 4 hours.

 

Key words: Hematology Test, Blood Volume, Postponed 4 Hours.

 

ABSTRAK

 

Volume sampel yang kurang dan penundaan dapat meningkatkan pembekuan darah dan menyebabkan trombosit mengalami agregasi (menempel dengan yang lainnya). Tujuan mengetahui apakah terdapat perbedaan antara hasil pemeriksaan hematologi jumlah trombosit pada volume sampel darah 3 ml, 2 ml, dan 1 ml dengan antikoagulan K2EDTA setelah ditunda 4 Jam pada orang sehat. Penelitian ini menggunakan metode analitik observasional dengan desain cross sectional. Hasil: Hasil rerata jumlah trombosit pada volume darah 1 ml dan 2 ml dalam tabung vacutaier K2EDTA yang ditunda selama 4 jam lebih tinggi dibandingkan dengan jumlah trombosit pada volume darah 3 ml. Tidak terdapat perbedaan bermakna jumlah terombosit pada sampel darah 3 ml, 2 ml, dan 1 ml pada tabung vacutainer K2EDTA setelah ditunda 4 jam.

 

Kata Kunci : Pemeriksaan Hematologi, Volume Darah, Ditunda 4 Jam.


Teks Lengkap:

Download Artikel

Referensi


Apriani, & Gea, H. P. (2021). Perbedaan Hitung Jumlah Trombosit Darah EDTA Dengan Penundaan Waktu Pemeriksaan. 2(1), 24–32.

Astuti, D., & Maharani, E. A. (2020). Nilai Indeks Trombosit sebagai Kontrol Kualitas Komponen Konsentrat Trombosit. Meditory, 8(4), 85–94.

Khasanah, A. N., & Suyadi. (2014). 2 1,2). 1(1), 17–22.

Kosasih, E.N., dan Kosasih, A.S., (2013). Tafsiran Hasil Pemeriksaan Laboratorium Klinik.Edisi 2. Tangerang: Karisma Publishing Group.

Lippi, G., Von Meyer, A., Cadamuro, J., & Simundic, A. M. (2019). Blood sample quality. Diagnosis, 6(1), 25–31. https://doi.org/10.1515/dx-2018-0018

Maripah, S. (2017). Pengaruh Penundaann Darah K3EDTA Terhadap Jumlah Trombosit Metode Automatic Hematology Analyzer. Unniversitas Muhammadiyah Semarang.

Sari, D. P., & Darmadi, D. (2018). Perbedaan Jumlah Leukosit Darah Edta Diperiksa Segera Dan Ditunda 2 Jam. Klinikal Sains : Jurnal Analis Kesehatan, 6(2), 30–36. http://jurnal.univrab.ac.id/index.php/klinikal/article/view/578

SyahDrajat. (2015). Panduan Menulis Tugas Akhir Kedokteran dan Kesehatan. Jakarta: Kencana.

Syuhada, S., Izzuddin, A., & Yudhistira, H. (2021). Perbandingan Trombosit dengan Antikoagulan K2EDTA. Jurnal Ilmiah Kesehatan Sandi Husada, 10(1), 170-176.

Supriyanto, W., & Iswandari, R. (2017). Kecenderungan sivitas akademika dalam memilih sumber referensi untuk penyusunan karya tulis ilmiah di perguruan tinggi. Berkala Ilmu Perpustakaan Dan Informasi, 13(1), 79-86.

Tadesse, H., Desta, K., Kinde, S., Hassen, F., & Gize, A. (2018). Errors in the Hematology Laboratory at St. Paul’s Hospital Millennium Medical College, Addis Ababa, Ethiopia. BMC Research Notes, 11(1), 1–5.https://doi.org/10.1186/s13104-018-3551-y

Tominik, V. I. (2017). Dampak Volume Darah Dalam Tabung K2Edta Dengan Hasil Jumlah Leukosit. Cambridge University Press, 53(9), 1–5.

Utami, A. (2017). Pengaruh Lama Simpan terhadap Jumlah Eritrosit pada Sediaan Whole Blood di Bank Darah RSUD Bendan Pekalongan. Tesis. Fakultas Ilmu Keperawatan dan Kesehatan UMS.Semarang.

Vives-Corrons, J.-L., Briggs, C., Simon-Lopez, R., Albarede, S., Salle, B. de la, Flegar-Meartii, Z., Nazor, A., Guyard, A., Lipsic, T., Nagai, Y., Patiu, M., Piqueras, J., Capel, M. J., Blerk, M. Van, Wang, J., & Marzac, C. (2014). Effect of EDTA-anticoagulated whole blood storage on cell morphologhy examination. A need for standardzation. International Journal of Phytoremediation, 20(1), 135–136. https://doi.org/10.1080/13518040701205365

Widyastuti, S. V. (2018). Perbedaan Jumlah Trombosit Darah Yang Segera Diperiksa, Di Tunda 4 Jam Pada Suhu 22°C Dan 28°C. Universitas Muhammadiyah Semarang, 53(9), 1689–1699.

Yaqin, M.A & Arista, D. (2015). Analisis Tahap Pemeriksaan Pra Analitik Sebagai Upaya Peningkatan Mutu Hasil Laboratorium Di Rs. Muji Rahayu Surabaya. Jurnal Sains, 5(10), 1–7.

Tamadita, S. (2020). Pengaruh Ekstrak Buah Kurma (Phoenix dactylifera) Varietas Ajwa Terhadap Peningkatan Jumlah Sel Trombosit Pada Tikus Putih Jantan Galur Wistar Yang Diinduksi Kotrimoksazol Sebagai Model Trombositopenia (Doctoral dissertation, Universitas Muhammadiyah Malang).

Xu, et al. (2010). Under-filled blood collection tubes containing K2EDTA as anticoagulant are acceptable for automated complete blood counts, white blood cell differential, and reticulocyte count. International Journal of Laboratory Hematology, 32(5), pp. 491–497. doi: 10.1111/j.1751-553X.2009.01211.x.




DOI: https://doi.org/10.33024/mahesa.v2i4.6429

Refbacks

  • Saat ini tidak ada refbacks.


Publisher: Universitas Malahayati Lampung


Creative Commons License
Semua artikel dapat digunakan dibawah lisensi Creative Commons Attribution-ShareAlike 4.0 International License


kostenlose besucherzähler